Solution for the disinfection and cleaning of rotary instruments
Solution for the disinfection and cleaning of rotary instruments
Fields of application
For the cleaning and desinfection of burs, cutters, diamond grinders and other rotating precision instruments.
Instructions for use
Rotasept® is used undiluted. Place the tools in the concentrate container without delay to prevent infectious residues from drying out on the instruments. Do not rinse the tools with water after immersion to avoid rust formation.
Using tweezers, place the instruments on a waterproof towel or paper towel and allow to dry. If necessary, remove any remaining contaminants with a brush and repeat the disinfection process. Do not exceed the recommended contact time. Replace the solution daily and in case of obvious infection. Please follow the recommendations of the tool manufacturers. Do not mix cleaning agents and disinfectants. Plastics sensitive to alkalis and alcohols, aluminum parts and tools with synthetic resin materials should not be placed on Rotasept®
Composition:
100 g Rotasept® contains: 1.6 g potassium hydroxide, 10 g 2-propanol, 0.1 g 2-ethylhexanol
Form:
Ready to use liquid
Packaging:
2lt
Efficacy | Concentration (%) | Contact time |
---|---|---|
Mycobactericidal (accordance with VAH) | Ready to use | 15 minutes |
Yeasticidal (accordance with VAH EN 13727, EN 14561, EN 13624, EN 14562) | Ready to use | 5 minutes |
Bactericidal (accordance with DVV (German Registered Association for Combating Viral Diseases)/ RKI Guideline 08/2008) | Ready to use | 5 minutes |
Virucidal (ΕΝ 14476) | Ready to use |
Description
Solution for the disinfection and cleaning of rotary instruments
Fields of application
For the cleaning and desinfection of burs, cutters, diamond grinders and other rotating precision instruments.
Instructions for use
Rotasept® is used undiluted. Place the tools in the concentrate container without delay to prevent infectious residues from drying out on the instruments. Do not rinse the tools with water after immersion to avoid rust formation.
Using tweezers, place the instruments on a waterproof towel or paper towel and allow to dry. If necessary, remove any remaining contaminants with a brush and repeat the disinfection process. Do not exceed the recommended contact time. Replace the solution daily and in case of obvious infection. Please follow the recommendations of the tool manufacturers. Do not mix cleaning agents and disinfectants. Plastics sensitive to alkalis and alcohols, aluminum parts and tools with synthetic resin materials should not be placed on Rotasept®
Composition:
100 g Rotasept® contains: 1.6 g potassium hydroxide, 10 g 2-propanol, 0.1 g 2-ethylhexanol
Form:
Ready to use liquid
Packaging:
2lt